ICRP110_HumanPhantoms Advanced Example

The ICRP110_HumanPhantoms example is developed and maintained by Susanna Guatelli, Matthew Large and Alessandra Malaroda,
Centre For Medical Radiation Physics (CMRP), University of Wollongong, NSW, Australia.

  Contacts:     
    - susanna@uow.edu.au 
    - mjl970@uowmail.edu.au
    - malaroda@uow.edu.au

The Geant4 example models the ICRP 110 reference computational human phantoms [1] and calculates
the dose in individual voxels and in entire organs. The example has been introduced in Geant4 10.7. 

The human male phantom is created from a whole-body clinical CT image set of a 38yr old 
individual with height 176 cm and mass approximately 70 kg. Similarly, the human female phantom was created from a set of 
whole body CT images of a 43yr old individual with height 163 cm and weight 60 kg. The CT scans were acquired with both 
individuals laying supine and with arms resting parallel alongside the body. Both sets of CT data were then scaled to 
closely approximate the ICRP adult Reference Male and Reference Female, defined in previous ICRP publications [2, 3]. 

The example is based on the extended/medical/DICOM example and  is documented in M. Large et al., "Modelling ICRP110 Adult Reference Voxel Phantoms for dosimetric applications: Development of a new Geant4 Advanced Example", Journal of Physics: Conference Series, Volume 1662, Micro-Mini & Nano Dosimetry and Innovative Technologies in Radiation Oncology - MMND ITRO 2020 10-16 February 2020, Wollongong, Australia. Available online: https://iopscience.iop.org/article/10.1088/1742-6596/1662/1/012021.  Note: If using this Geant4 advanced example, it is kindly asked to cite this paper and Reference [1].

How to use the  example is described in detail in the README file.

For any enquiry, please contact Susanna Guatelli (susanna@uow.edu.au).

Male and Female models of the ICRP110Phantoms modelled in Geant4

Figure 1: Male and Female ICRP110 Phantoms modelled in Geant4. 

Acknowledgments

The authors acknowledge that this Geant4 application has been implemented with the kind permission of 
the International Commission on Radiological Protection (ICRP). 

All data files used for the modelling of the anatomies in Geant4 were obtained from the ICRP's website on publication 110 under "Supplementary Data". Available online at https://www.icrp.org/publication.asp?id=ICRP%20Publication%20110. 

References

 [1] HG Menzel, C Clement, and P DeLuca. ICRP publication 110. "Realistic reference phantoms:
    an icrp/icru joint effort: A report of adult reference computational phantoms", Annals of the
    ICRP, 39(2):1, 2009. URL: http://www.icrp.org/publication.asp?id=icrp%20publication%20110.
 
  [2] Valetin J 2002 Basic anatomical and physiological data for use in radiological protection: 
  reference values: ICRP Publication 89 Ann. ICRP vol. 32 (Oxford: Elsevier) pp 1-277.

  [3] Valetin J 2007 The 2007 recommendations of the international commission on radiological 
  protection Ann. ICRP vol 37 (Oxford: Elsevier) pp 1-133.